Technology
|
|
IEEE802.3 10Base-T IEEE802.3u 100Base-TX IEEE802.3u 100Base-FX IEEE802.3x flow control
|
|
|
Store and forward technology and with 3.2Gbps switch fabric
|
|
Aggregate System Throughput
|
|
|
Interface
|
|
4 x 10/100 Base-TX with Auto MDI/MDI-X, Auto-Negotiation function 1 x 100Base-FX supports multi-mode or single mode fiber
|
|
|
10/100 Base-TX: RJ-45 100Base-FX: Duplex SC Power/Relay: 4-pin terminal block
|
|
|
RJ-45 connector: supports Cat.3, Cat.4, Cat.5 unshielded twisted pair or shielded twisted pair cable.The link distance is maximum 100 meters. Fiber: SC, multi-mode or single-mode Multi-mode fiber: 50/125um or 62.5/125um, max. distance 2KM Single-mode fiber: 8/125um, 9/125um or 10/125 um, max. distance 30KM
|
|
|
JetNet 2005f-m, multi-mode fiber Link Distance: 2KM (Max.) Wave-length: 1310nm Min Tx Power:-20dBm Max Tx Power:-14dBm Min Rx Sensitivity:0dBm Max Rx Sensitivity:-31dBm Link budget:11dBm JetNet 2005f-s, single-mode fiber Link Distance: 30KM (Max.) Wave-length:1310nm Min Tx Power:-15dBm Max Tx Power:-8dBm Min Rx Sensitivity:0dBm Max Rx Sensitivity:-34dBm Link budget:19dBm
|
|
|
DIP 1~5: Port Event Alarm Control On: Enable port link down alarm. Off: Disable port link down alarm.
|
|
|
System: Power (green), Fault (red on) RJ-45 port: 100Mbps Link (green on)/Activity(green flashing) 10Mbps Link (yellow on)/Activity(yellow flashing)
|
|
Power Requirements
|
|
DC 18~32V with reverse polarity protection
|
|
|
|
Mechanical
|
|
|
|
Aluminum case with IP31 protection
|
|
|
111.8mm(H) x 30mm (W) x 98.2mm (D) (with DIN rail clip) 111.8mm(H) x 30mm (W) x 89.4mm (D) (without DIN rail clip)
|
|
|
377g with package 295g without package
|
|
Environmental
|
|
-10~ 60°C (JetNet 2005f) -40~ 75°C (JetNet 2005f-w)
|
|
|
0% to 95% (Non-condensing)
|
|
|
|
|
1.5KV for all ports and power
|
|
Regulatory Approvals
|
|
|
|
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8
|
|
|
|
|
|
|
|
|
|
|
713,506 Hours, MIL-HDBK-217F GB standard
|
|
|
|